RADIOGRAPHIC IMAGE QUALITY ANALYSIS IN THORAX, ABDOMEN, AND BONE FRACTURE EXAMINATIONS WITH KV AND MAS PARAMETER VARIATIONS
Main Article Content
Zahra Putri Rahman
Rhamdani Syahputra
Nani Lasiyah
This experimental study at Petala Bumi Public Hospital (Jan–Apr 2025) aimed to determine the optimal tube voltage (kV) and tube current–time product (mAs) settings to enhance conventional X-ray image quality for thoracic, abdominal, and bone fracture examinations. Radiographs were taken using varied kV–mAs combinations and analyzed with ImageJ software through grey-level histograms to assess brightness (mean pixel intensity) and contrast (standard deviation). The thoracic image with a mean of 127.117 and SD of 83.331 showed the best balance of brightness and contrast. The optimal abdominal image had a mean of 107.703 and SD of 66.725, while the best bone fracture image had an SD of 65.463, ensuring clear fracture visibility. The study confirms the effectiveness of ImageJ in objective image-quality evaluation and highlights the importance of adjusting exposure parameters to improve diagnostic clarity without increasing radiation dose.
Azis, y., & nababan, s. (2019). Analisa faktor ma pada pesawat x-ray general merk allengers type 325. Jurnal mutiara elektromedik, 3(2), 32–37.
Badan Pengawas Tenaga Nuklir. (2019). Buku Panduan Perizinan Pesawat Sinar-X Radiologi Diagnostik dan Intervensional. Jakarta: Subdirektorat Perizinan Fasilitas Kesehatan, Direktorat Perizinan Fasilitas Radiasi dan Zat Radioaktif.
Bebbington, N. A., Jørgensen, T., Dupont, E., & Micheelsen, M. A. (2021). Validation of CARE kV automated tube voltage selection for PET-CT: PET quantification and CT radiation dose reduction in phantoms. EJNMMI Physics, 8(29).
Brenda Putri Meliana, Arif Wahyu Setyo Budi, & Rahmawanto. (2024). Pengaruh Pemasangan Balut Bidai dan Relaksasi Nafas Dalam terhadap Penurunan Skala Nyeri pada Pasien Fraktur.
Dewi, P., Ratini, N., & Trisnawati, N. (2022). Effect of x-ray tube voltage variation to value of contrast to noise ratio (cnr) on computed tomography (ct) scan at rsud bali mandara. International Journal of Physical Sciences and Engineering, 6(2), 82-90.
Endah Savitri, R., & Sunarno. (2014). Optimasi Faktor Eksposi Pada Sistem Radio Optimasi Faktor Eksposi Pada Sistem Radiografi Grafi Digital Menggunakan Analisis CNR ( Contrast To Noise Ratio ). Unnes Physics Journal.
Fitriyani, F., Suharyana, Muhtarom, Riyatun (2017). Pengaruh focus film distance terhadap kesesuaian berkas radiasi pada pesawat x-ray simulator di instalasi radioterapi rsud dr. Moewardi surakarta.
Gustia, r. M. (2021). Analisis sebaran radiasi hambur pesawat sinar x konvensional di instalasi radiologi rsia zainab.
Prasetyo. B.D. 2020. Klasifikasi Citra X-Ray Paru-Paru Anak Pneumonia Dan Non-Pneumonia Menggunakan Metode Segmentasi Dan Deteksi Tepi.
Prastanti A. D., Abimanyu B., Nino A., (2020). Optimasi citra cr dan limitasi dosis dengan pengaturan kolimasi pada radiograf servikal. Rasad, Sjahriar. 2016. Radiologi Diagnostik. Jakarta:Balai Penerbit FKUI.